Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Test Anal ; 15(5): 551-565, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36647693

RESUMO

Recent research reported that lurasidone degrades in unpreserved ante-mortem human whole blood inoculated with microorganisms known to dominate postmortem blood specimens. In vitro degradation occurred at a similar rate to risperidone, known to degrade in authentic postmortem specimens until below analytical detection limits. To identify the lurasidone degradation products formed, an Agilent 6520 liquid chromatograph quadrupole-time-of-flight mass spectrometer (LC-QTOF-MS) operating in auto-MS/MS mode was used. Numerous degradation products not previously reported in prior in vitro or in vivo pharmacokinetic studies or forced degradation studies were detected. Accurate mass data, mass fragmentation data, acetylation experiments, and a proposed mechanism of degradation analogous to risperidone supports initial identification of the major degradation product as N-debenzisothiazole-lurasidone (calculated m/z [M + H]+ = 360.2646). A standard was unavailable to conclusively confirm this identification. Retrospective data analysis of postmortem cases involving lurasidone identified the presence of the major degradation product in four of six cases where lurasidone was also detected. This finding is significant for toxicology laboratories screening for this drug in postmortem casework. The major postmortem lurasidone degradation product has consequently been added to the LC-QTOF-MS drug screen at Forensic Science SA (FSSA) to indicate postmortem lurasidone degradation in authentic postmortem blood specimens and as a marker of lurasidone administration in the event lurasidone is degraded to concentrations below detection limits.


Assuntos
Cloridrato de Lurasidona , Espectrometria de Massas em Tandem , Humanos , Risperidona , Estudos Retrospectivos , Toxicologia Forense
2.
Drug Test Anal ; 15(2): 220-234, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36269160

RESUMO

A systematic study was performed into the degradation of ziprasidone in simulated postmortem blood. Fifteen potential degradation products not previously reported in the literature were observed. Four resulted from degradation in human blood, whereas the remaining products resulted from reaction with solvents: four from alkaline degradation, four from reaction with acetaldehyde, and three from reaction with acetone. To identify possible degradation products, a liquid chromatograph-diode array detector (LC-DAD) and liquid chromatograph quadrupole-time-of-flight mass spectrometer (LC-QTOF-MS) operating in auto-MS/MS mode were used. It was indicated from red-shifted UV-Vis spectra, accurate mass data, mass fragmentation data, and a deuteration experiment that the site of ziprasidone degradation, in the in vitro blood experiments, was the methylene carbon of the oxindole moiety. The major in vitro blood degradation products were proposed to be E/Z isomers of 3-ethylidene-ziprasidone. Further, another in vitro degradation product in microbially inoculated blood specimens was proposed to be 3-ethyl-ziprasidone. 3-Ethylidene-ziprasidone was hypothesized to form from the reaction of ziprasidone with acetaldehyde derived from the ethanol used to spike ziprasidone into the in vitro blood experiments. Data from two postmortem investigations were available for retrospective reanalysis. Attempts were made to detect degradation products of ziprasidone, but none were found.


Assuntos
Piperazinas , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Estudos Retrospectivos , Cromatografia Líquida/métodos , Cromatografia Líquida de Alta Pressão/métodos
3.
Drug Test Anal ; 14(7): 1200-1222, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35170234

RESUMO

In the postmortem environment, some drugs and metabolites may degrade due to microbial activity, even forming degradation products that are not produced in humans. Consequently, underestimation or overestimation of perimortem drug concentrations or even false negatives are possible when analyzing postmortem specimens. Therefore, understanding whether medications may be susceptible to microbial degradation is critical in order to ensure that reliable detection and quantitation of drugs and their degradation products is achieved in toxicology screening methods. In this study, a "simulated postmortem blood" model constructed of antemortem human whole blood inoculated with a broad population of human fecal microorganisms was used to investigate the stability of 17 antidepressant and antipsychotic drugs. Microbial communities present in the experiments were determined to be relevant to postmortem blood microorganisms by 16S rRNA sequencing analyses. After 7 days of exposure to the community at 37°C, drug stability was evaluated using liquid chromatography coupled with diode array detection (LC-DAD) and with quadrupole time-of-flight mass spectrometry (LC-QTOF-MS). Most of the investigated drugs were found to be stable in inoculated samples and noninoculated controls. However, the 1,2-benzisothiazole antipsychotics, ziprasidone and lurasidone, were found to degrade at a rate comparable with the known labile control, risperidone. In longer experiments (7 to 12 months), where specimens were stored at -20°C, 4°C, and ambient temperature, N-dealkylation degradation products were detected for many of the drugs, with greater formation in specimens stored at -20°C than at 4°C.


Assuntos
Antipsicóticos , Psicotrópicos , Cromatografia Líquida , Estabilidade de Medicamentos , Toxicologia Forense/métodos , Humanos , Espectrometria de Massas , Psicotrópicos/análise , RNA Ribossômico 16S
4.
J Expo Sci Environ Epidemiol ; 32(3): 343-355, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34274958

RESUMO

The popularity of tattooing has increased significantly over recent years. This has raised concerns about the safety of tattoo inks and their metabolites/degradation products. The photolytic and metabolic degradation of tattoo pigments may result in the formation of toxic compounds, with unforeseen health risks. A systematic literature review was undertaken to determine the current state of knowledge of tattoo pigments' degradation products when irradiated with sunlight, laser light or metabolised. The review demonstrates that there is a lack of knowledge regarding tattoo pigment degradation/metabolism, with only eleven articles found pertaining to the photolysis of tattoo pigments and two articles on the metabolism of tattoo pigments. The limited research indicates that the photolysis of tattoo pigments could result in many toxic degradation products, including hydrogen cyanide and carcinogenic aromatic amines.


Assuntos
Tatuagem , Corantes/efeitos da radiação , Humanos , Tinta , Lasers , Luz Solar
5.
J Environ Radioact ; 234: 106627, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33964669

RESUMO

Data on the uptake of elements and radionuclides by flora from soils in arid environments are underrepresented in international databases, especially when comparing across seasons. This study improved the understanding on the uptake of natural uranium-series radionuclides, as well as more than 30 elements, in a range of Australian native flora species that are internationally representative of an arid/semi-arid zone (e.g. Acacia, Astrebla, Atriplex, and Dodonea). Results indicate that the soil-to-plant uptake ratios were generally higher when compared with international data for grasses and shrubs from more temperate environments. The majority of the elemental concentrations in grasses were higher in winter than in summer and the opposite trend was found in shrubs, which suggests that the season of collection potentially introduces variability in the reported concentration ratios. The data also suggest that grasses, being dominant and widespread species in arid zones, may be effective as a reference organism to ensure comparative assessment across sites of interest. The results of this study will improve the confidence of environmental assessments in arid zones.


Assuntos
Monitoramento de Radiação , Austrália , Radioisótopos , Estações do Ano , Solo
6.
Forensic Sci Int ; 316: 110472, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32919164

RESUMO

Xylitol is a polyhydric alcohol that may be nitrated to form an explosive (xylitol pentanitrate or XPN). Consequently, forensic and first response personnel may encounter XPN in post-blast residues or as a bulk material. Despite this, key analytical data for XPN that may be used in first response or forensic operations to aid its detection are not yet available in the literature. The present article provides infrared spectrometry, Raman spectrometry, nuclear magnetic resonance spectrometry, chromatography and mass spectrometry data in order to address this knowledge gap.

7.
PLoS One ; 12(10): e0185252, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29045459

RESUMO

Many archaeological science studies use the concept of "provenance", where the origins of cultural material can be determined through physical or chemical properties that relate back to the origins of the material. Recent studies using DNA profiling of bacteria have been used for the forensic determination of soils, towards determination of geographic origin. This manuscript presents a novel approach to the provenance of archaeological minerals and related materials through the use of 16S rRNA sequencing analysis of microbial DNA. Through the microbial DNA characterization from ochre and multivariate statistics, we have demonstrated the clear discrimination between four distinct Australian cultural ochre sites.


Assuntos
Arqueologia , Geografia , RNA Ribossômico 16S/genética , Análise de Sequência de DNA/métodos , Microbiologia do Solo , Solo/química , Austrália , Filogenia , Análise de Componente Principal
8.
Sci Rep ; 7(1): 2512, 2017 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-28566707

RESUMO

A new urea functionalised 4-amino-1,8-naphthalimide based fluorescent anion sensor was synthesised in 64% yield over three steps. Fluorescence and 1H NMR titrations showed that the sensor complexes strongly with acetate and dihydrogen phosphate and to a lesser extent bromide. The corresponding binding stoichiometries were examined using 1H NMR titrations. Results show that the sensor molecule initially forms 1:1 complexes through hydrogen bonding to the urea moiety, followed by secondary complexation to form higher order host:guest stoichiometries. Specifically, oxyanions complex to the sensor via hydrogen bonding through synergistic aryl C-H and N-H anion interactions in a 1:2 sensor:oxyanion arrangement. Furthermore, 2:1 sensor:oxyanion complexes are formed through an oxyanion linkage between two urea functionalities on different host molecules. This contrasts the majority of previous reports for similar hosts, which indicate 1:1 binding stoichiometry.

9.
Analyst ; 141(12): 3657-67, 2016 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-26999774

RESUMO

This manuscript presents the first non-destructive synchrotron micro-X-ray fluorescence study of natural mineral pigments on Aboriginal Australian objects. Our results demonstrate the advantage of XFM (X-ray fluorescence microscopy) of Aboriginal Australian objects for optimum sensitivity, elemental analysis, micron-resolution mapping of pigment areas and the method also has the advantage of being non-destructive to the cultural heritage objects. Estimates of pigment thickness can be calculated. In addition, based on the elemental maps of the pigments, further conclusions can be drawn on the composition and mixtures and uses of natural mineral pigments and whether the objects were made using traditional or modern methods and materials. This manuscript highlights the results of this first application of XFM to investigate complex mineral pigments used on Aboriginal Australian objects.

10.
Anal Bioanal Chem ; 408(8): 2009-17, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26781099

RESUMO

We report the use of auto-sampler programmable functions to co-inject analyte standard solution and matrix extract to assess ion enhancement and suppression (matrix effects) in LC-MS. This is effectively an automated post-extraction addition (APEA) procedure, emulating the manual post-extraction addition (PEA) approach widely adopted for assessment of matrix effects. To verify that APEA was comparable to the conventional PEA approach, matrix effects were determined using both methods for a selection of 31 illicit and pharmaceutical drugs in 10 different human urine extracts. Matrix effects measured using APEA were statistically indistinguishable from manual PEA methodology for 27 of the 31 drugs. Of the four drugs that showed significant differences using the two methods, three differed by less than 2 %, which is within the expected accuracy limits required for matrix effect determinations. The remaining analyte, trimeprazine, was found to degrade in the spiked PEA matrix extract, accounting for the difference between matrix effects measured by the PEA and APEA approaches. APEA enables a single matrix extract to be assessed at multiple analyte concentrations, resulting in a considerable reduction in sample preparation time. In addition, APEA can reduce the quantity of analyte-free sample matrix required for matrix effect assessment, which is an important consideration in certain analytical and bioanalytical fields. This work shows that APEA may be considered as an acceptable alternative to PEA for the assessment of matrix effects in LC-MS method validation and may be applicable to a variety of matrices such as environmental samples.


Assuntos
Cromatografia Líquida/instrumentação , Espectrometria de Massas/instrumentação , Preparações Farmacêuticas/sangue , Preparações Farmacêuticas/urina , Detecção do Abuso de Substâncias/instrumentação , Cromatografia Líquida/métodos , Desenho de Equipamento , Análise de Injeção de Fluxo/instrumentação , Análise de Injeção de Fluxo/métodos , Humanos , Drogas Ilícitas/sangue , Drogas Ilícitas/urina , Limite de Detecção , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos
11.
Phytochem Anal ; 26(6): 454-60, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26219427

RESUMO

INTRODUCTION: Plant extracts containing high levels of antioxidants are desirable due to their reported health benefits. Most techniques capable of determining the antioxidant activity of plant extracts are unsuitable for rapid at-line analysis as they require extensive sample preparation and/or long analysis times. Therefore, analytical techniques capable of real-time or pseudo real-time at-line monitoring of plant extractions, and determination of extraction endpoints, would be useful to manufacturers of antioxidant-rich plant extracts. OBJECTIVES: To develop a reliable method for the rapid at-line extraction monitoring of antioxidants in plant extracts. MATERIALS AND METHODS: Calendula officinalis extracts were prepared from dried flowers and analysed for antioxidant activity using sequential injection analysis (SIA) with chemiluminescence (CL) detection. The intensity of CL emission from the reaction of acidic potassium permanganate with antioxidants within the extract was used as the analytical signal. The SIA-CL method was applied to monitor the extraction of C. officinalis over the course of a batch extraction to determine the extraction endpoint. Results were compared with those from ultra high performance liquid chromatography (UHPLC). RESULTS: Pseudo real-time, at-line monitoring showed the level of antioxidants in a batch extract of Calendula officinalis plateaued after 100 min of extraction. These results correlated well with those of an offline UHPLC study. CONCLUSION: SIA-CL was found to be a suitable method for pseudo real-time monitoring of plant extractions and determination of extraction endpoints with respect to antioxidant concentrations. The method was applied at-line in the manufacturing industry.


Assuntos
Antioxidantes/análise , Calendula/química , Cromatografia Líquida de Alta Pressão/métodos , Extratos Vegetais/química , Luminescência
12.
Phytother Res ; 29(1): 120-4, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25266574

RESUMO

The in vitro safety and antioxidant potential of Calendula officinalis flower head extracts was investigated. The effect of different concentrations (0.125, 0.5, 1.0, 2.0 and 5.0% (v/v)) of Calendula extracts on human skin cells HaCaT in vitro was explored. Doses of 1.0% (v/v) (0.88 mg dry weight/mL) or less showed no toxicity. Cells were also exposed to the Calendula extracts for either 4, 24 or 48 h before being exposed to an oxidative insult (hydrogen peroxide H2 O2 ) for 1 h. Using the MTT cytotoxicity assay, it was observed that two independent extracts of C. officinalis gave time-dependent and concentration-dependent H2 O2 protection against induced oxidative stress in vitro using human skin cells. Pre-incubation with the Calendula extracts for 24 and 48 h increased survival relative to the population without extract by 20% and 40% respectively following oxidative challenge. The antioxidant potential of the Calendula extracts was confirmed using a complimentary chemical technique, the DPPH(●) assay. Calendula extracts exhibited free radical scavenging abilities. This study demonstrates that Calendula flower extracts contain bioactive and free radical scavenging compounds that significantly protect against oxidative stress in a human skin cell culture model.


Assuntos
Calendula/química , Estresse Oxidativo/efeitos dos fármacos , Extratos Vegetais/farmacologia , Pele/efeitos dos fármacos , Antioxidantes/farmacologia , Linhagem Celular , Flores/química , Humanos , Peróxido de Hidrogênio/efeitos adversos , Pele/citologia
13.
Anal Bioanal Chem ; 407(1): 95-116, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25381608

RESUMO

Blooms of microscopic algae in our waterways are becoming an increasingly important environmental concern. Many are sources of harmful biotoxins that can lead to death in humans, marine life and birds. Additionally, their biomass can cause damage to ecosystems such as oxygen depletion, displacement of species and habitat alteration. Globally, the number and frequency of harmful algal blooms has increased over the last few decades, and monitoring and detection strategies have become essential for managing these events. This review discusses developments in the use of oligonucleotide-based 'molecular probes' for the selective monitoring of algal cell numbers. Specifically, hybridisation techniques will be a focus.


Assuntos
Bioensaio/métodos , Dinoflagellida/genética , Dinoflagellida/isolamento & purificação , Monitoramento Ambiental/métodos , Proliferação Nociva de Algas , Oligonucleotídeos/genética , Dinoflagellida/crescimento & desenvolvimento , Hibridização in Situ Fluorescente
14.
Environ Sci Technol ; 48(10): 5737-44, 2014 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-24779406

RESUMO

Understanding the form in which gold is transported in surface- and groundwaters underpins our understanding of gold dispersion and (bio)geochemical cycling. Yet, to date, there are no direct techniques capable of identifying the oxidation state and complexation of gold in natural waters. We present a reversed phase ion-pairing HPLC-ICP-MS method for the separation and determination of aqueous gold(III)-chloro-hydroxyl, gold(III)-bromo-hydroxyl, gold(I)-thiosulfate, and gold(I)-cyanide complexes. Detection limits for the gold species range from 0.05 to 0.30 µg L(-1). The [Au(CN)2](-) gold cyanide complex was detected in five of six waters from tailings and adjacent monitoring bores of working gold mines. Contrary to thermodynamic predictions, evidence was obtained for the existence of Au(III)-complexes in circumneutral, hypersaline waters of a natural lake overlying a gold deposit in Western Australia. This first direct evidence for the existence and stability of Au(III)-complexes in natural surface waters suggests that Au(III)-complexes may be important for the transport and biogeochemical cycling of gold in surface environments. Overall, these results show that near-µg L(-1) enrichments of Au in environmental waters result from metastable ligands (e.g., CN(-)) as well as kinetically controlled redox processes leading to the stability of highly soluble Au(III)-complexes.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ouro/análise , Espectrofotometria Atômica/métodos , Água/química , Cianatos/análise , Hidrólise , Lagos/química , Ligantes , Termodinâmica , Fatores de Tempo , Austrália Ocidental
15.
Anal Chim Acta ; 803: 194-203, 2013 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-24216215

RESUMO

We report a pyrolysis GC-MS method capable of analysing Indigenous Australian and European binders typically used in the manufacture of culturally important painted works. Eleven different traditional European binders and ten different Indigenous Australian binders were examined. The method allows discrimination between highly complex and impure lipid, resin, polysaccharide, wax, and protein-based binders. Each was found to have characteristic pyrolysis products that were unique to the binder material, demonstrating the potential for differentiation of these binders on Australian Aboriginal artworks towards identification and conservation of cultural heritage.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Pintura/análise , Arte , Austrália , Análise por Conglomerados , Técnicas Eletroquímicas , Europa (Continente)
16.
Analyst ; 138(22): 6954-61, 2013 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-24087827

RESUMO

Here we use short-end electrokinetic injection capillary electrophoresis (CE) to investigate the free solution mobility of short strands of double-stranded oligonucleotides (dsODNs) on polymer modified capillaries. Single base pair (bp) resolution (Rs) of dsODNs ranging from 16-20 bp was achieved in free solution on an 8 cm capillary dynamically coated with poly(ethylpyrrolidine methacrylate-co-methyl methacrylate) (PEPyM-co-PMMA) random copolymer. Interestingly, separation of a dsODN mixture containing two 16 bp strands of different sequences resulted in partial resolution (0.52) implying that the free solution mobility of dsODNs was sequence dependent. The single bp resolution achieved for the complementary sequence strands (the sequence of all strands in the mixtures contained the same 16 bp sequence) was improved by up to 37% for separation of dsODNs containing non-complementary sequences. The 16 bp peak was not additive within each mixture, indicating the presence of ODN-ODN interactions. Investigation of these interactions (and ODN-buffer interactions) showed that they can be influenced by the ionic strength and conductivity of the background electrolyte (BGE). Increasing the ionic strength reduced the ODN-ODN interactions and improved the resolution, whereas, increasing the conductivity reduced ODN-buffer interactions, increasing the mobility, at the consequence of promoting ODN-ODN interactions, and hence decreasing the resolution.


Assuntos
Eletroforese Capilar , Oligonucleotídeos/química , Polímeros/química , Espectroscopia de Ressonância Magnética , Propriedades de Superfície , Fatores de Tempo
17.
Analyst ; 138(15): 4275-9, 2013 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-23749030

RESUMO

We demonstrate the use of injected gallium electrodes for capacitively coupled contactless conductivity detection (C(4)D) within a microchip electrophoresis device. Evaluation of the electrodes for quantitative detection of electrophoretically separated lithium, sodium and potassium ions showed the system offers competitive detection limits of 6.1 × 10(-6) M, 6.7 × 10(-6) M and 8.5 × 10(-6) M, respectively. The fabrication process is fast, highly reproducible, and eliminates difficulties with electrode alignment. Using this approach C(4)D can be readily achieved in any microchip by simply adding extra 'electrode' channels to the microchip design.

18.
Electrophoresis ; 33(7): 1205-14, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22539324

RESUMO

Here we describe a capillary electrophoretic method for the separation of double-stranded oligonucleotides (ds-ODNs) ranging from 16-20 bp with 2 bp resolution using a low concentration of poly(ethylpyrrolidine methacrylate-co-methyl methacrylate) (PEPyM-co-PMMA) copolymer physically adsorbed to a capillary surface. Contrary to traditional DNA separations, we show that the ds-ODN with the highest molecular size eluted first and propose that this phenomena is due to a screening effect by the PEPyM-co-PMMA coating on the smaller ds-ODNs negative charge during elution. Key to the performance of this separation was a sample preparation time of less than 1 h and analysis time of 40 min. Repeatability of intraday migration time for the mixtures was typically < 1% relative standard deviation (n = 3). In addition, we demonstrate that the coating has an acceptable capillary lifetime of over 70 injections.


Assuntos
Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Oligonucleotídeos/isolamento & purificação , Ácidos Polimetacrílicos/química , Pirróis/química , Oligonucleotídeos/química , Reprodutibilidade dos Testes , Temperatura
19.
Talanta ; 88: 743-8, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-22265569

RESUMO

A simple controlled chemical reduction of 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX) and related nitramine compounds with zinc amalgam generates species that elicit intense chemiluminescence with tris(2,2'-bipyridine)ruthenium(III), which extends this widely utilised chemiluminescence reagent to a new class of analyte and presents a sound chemical basis for a screening test for nitramine high explosives. Examination of the chemiluminescence profiles under stopped-flow conditions revealed contributions from multiple transient species formed in the initial reduction step.


Assuntos
2,2'-Dipiridil/análogos & derivados , Compostos de Anilina/análise , Substâncias Explosivas/análise , Nitrobenzenos/análise , Compostos Organometálicos/química , Triazinas/análise , 2,2'-Dipiridil/química , Análise de Injeção de Fluxo , Medições Luminescentes , Cloreto de Mercúrio/química , Zinco/química
20.
Biomicrofluidics ; 6(2): 26503, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23761843

RESUMO

Herein, we describe the development of a novel primer system that allows for the capture of double-stranded polymerase chain reaction (PCR) amplification products onto a microfluidic channel without any preliminary purification stages. We show that specially designed PCR primers consisting of the main primer sequence and an additional "tag sequence" linked through a poly(ethylene glycol) molecule can be used to generate ds-PCR amplification products tailed with ss-oligonucleotides of two forensically relevant genes (amelogenin and human c-fms (macrophage colony-stimulating factor) proto-oncogene for the CSF-1 receptor (CSF1PO). Furthermore, with a view to enriching and eluting the ds-PCR products of amplification on a capillary electrophoretic-based microfluidic device we describe the capture of the target ds-PCR products onto poly(dimethylsiloxane) microchannels modified with ss-oligonucleotide capture probes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...